131 Multi-product control SINGLE- OR DUAL-CIRCUIT CONTROL (VALVE) - CONTROLBOX ELECTRONIC CONTROL OF 3- AND 4-WAY VALVES - TEX 33 DOMESTIC HOT WATER (DHW) CONTROL - RS 3100 Description • Navistem 200S control • Single- or dual-circuit control • Analogue valve control in response to outdoor and/or room temperature • Focus on sliding DHW • Control for 2 independent circuits: either 2 circuits for circulating pumps or 1 circuit for a valve and 1 circuit for a circulating pump, 2 circuits for a valve Composition • Wall-mounted connection box • AVS 37.294 user interface • RVS 53.183 control box • T55 room sensor (wired) • QAC 34 outdoor sensor • QAZ 36 boiler sensor • QAD 36 flow sensor • QAZ 36 water heating sensor • M 67 motor valve 2nd circuit accessories kit for ControlBox valve • T55 room sensor (wired) • QAD 36 outlet sensor • M 67 motor valve Description • Electronic valve control in response to room temperature • Digital display • 3 optional temperatures for daytime, nighttime and frost protection • Selection of operating modes that run daily or weekly • Day/Night and frost protection override buttons • Holiday mode • Optional telephone modem connection Composition • REV 33 digital room thermostat • Connection box • 3-point motor Description • DHW control with 4-minute postcirculation after tank charging • Off/frost protection functions, range of set-point temperatures (55°C to 75 °C) • Anti-legionella programming • Day/Night and frost protection override buttons Composition • Tank-supplied DHW control box • DHW sensor • Boiler sensor • Pre-wired harness