816 1,723.3 AIR 953 816 1,723.3 AIR 953 816 1,723.3 AIR 953 Outdoor units 12, 15, 17 kW 543 573 765 690 1,364.5 664 1,022.5 61.5 543 573 765 22.5 61.5 View from below View from above Front view Side view View from above Detailed hydraulics and electrical diagrams included in the installation manual. INSTALLATION SCHEMATICS A - IXTRA M COMPACT: 1 HEATING ZONE 1 Outdoor unit and floor stand* 2 Hydraulics connections* 3 Buffer tank* 4 Built-in electric booster heater 5 Modulating thermostat* 6 Outdoor sensor (or Smart Adapt) 7 Anti-freeze valve* 8 Pump* *Options, see pages 69 to 72. Pg AE SSe SR VAG VAG R UH SA SA VE C SD Db BT 1 6 3 2 4 7 5 5 8 CAR B - IXTRA M COMPACT: 2 HEATING ZONES + DHW TANK 1 Outdoor unit and floor stand* 2 Hydraulics connections* 3 Buffer tank* 4 Built-in electric booster heater 5 Modulating thermostat* 6 Outdoor sensor (or Smart Adapt) 7 Anti-freeze valve* 8 Pump* *Options, see pages 69 to 72. SA SA Pg AE SSe SR VAG VAG UH SSe VE C SD Db BT M CAR CAR K2C VM CM BD C SDM GS MT CAR D AE VD SSa KS 1 6 3 2 4 7 5 5 8 27 Heat pumps
RkJQdWJsaXNoZXIy NTAwMTk1