Atlantic Comfort - Heat pumps catalogue 2025

(1) Includes accessories depending on the selected solution. (2) Noise pressure at 5 m from the appliance, 1.5 m from the ground, free field, directivity index of 2. ErP TECHNICAL SPECIFICATIONS AND PERFORMANCE DESCRIPTION UNIT COMPACT 5 COMPACT 6 COMPACT 8 COMPACT 11 SMART SYSTEM 5 SMART SYSTEM 6 SMART SYSTEM 8 SMART SYSTEM 11 SMART SYSTEM DUO 5 SMART SYSTEM DUO 6 SMART SYSTEM DUO 8 SMART SYSTEM DUO 11 Refrigerant R32 R32 R32 R32 R32 R32 R32 R32 R32 R32 R32 R32 SPECIFICATIONS AND HEATING PERFORMANCE Energy class - heating (35°C/55°C) - A+++/ A++ A+++/ A++ A+++/ A++ A+++/ A++ A+++/ A++ A+++/ A++ A+++/ A++ A+++/ A++ A+++/ A++ A+++/ A++ A+++/ A++ A+++/ A++ Seasonal energy efficiency - heating (35°C/55°C) including outdoor sensor % 186/127 181/135 197/141 197/143 186/127 191/135 197/141 197/143 186/127 191/135 197/141 197/143 SCOP (Seasonal Coefficient of Performance) 35°C/55°C 4.66/ 3.21 4.81/ 3.39 4.95/ 3.54 4.96/ 3.61 4.66/ 3.21 4.81/ 3.39 4.95/ 3.54 4.96/ 3.61 4.66/ 3.21 4.81/ 3.39 4.95/ 3.54 4.96/ 3.61 Acoustic power (indoors/outdoors) dB(A) 40/52 40/52 40/56 40/57 40/52 40/52 40/56 40/57 40/52 40/52 40/56 40/57 GENERAL SPECIFICATIONS Max. start temperature °C 60 60 60 60 60 60 60 60 60 60 60 60 Heating capacity +7°C/+35°C max. kW 4 5 8 10 4 5 8 10 4 5 8 10 COP (Coefficient of Performance) +7°C/+35°C 5.03 4.99 5.08 4.70 5.03 4.99 5.08 4.70 5.03 4.99 5.08 4.70 Heating capacity -7°C/+35°C max. kW 4.10 5.10 8.18 9.53 4.10 5.10 8.18 9.53 4.10 5.10 8.18 9.53 COP (Coefficient of Performance) -7°C/+35°C nominal 2.93 2.92 3.03 2.95 2.93 2.92 3.03 2.95 2.93 2.92 3.03 2.95 Heating capacity -7°C/+55°C kW 3.7 4.80 7.50 8.50 3.7 4.80 7.50 8.50 3.7 4.80 7.50 8.50 COP (Coefficient of Performance) -7°C/+55°C 1.77 1.91 2.07 2.07 1.77 1.91 2.07 2.07 1.77 1.91 2.07 2.07 Electric booster heater output kW 3 3 3 3 3 3 3 3 3 3 3 3 OUTDOOR UNIT Sound rating(2) dB(A) 30 30 34 35 30 30 34 35 30 30 34 35 Weight kg 85 85 110 110 85 85 110 110 85 85 110 110 Refrigerant factory load kg 0.88 0.88 1.47 1.47 0.88 0.88 1.47 1.47 0.88 0.88 1.47 1.47 Quantity in tonnes of CO2 equivalent t 0.59 0.59 0.99 0.99 0.59 0.59 0.99 0.99 0.59 0.59 0.99 0.99 HYDRAULICS CONNECTIONS Outdoor/Indoor unit input and output diameters "in." 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 Recommended max. length m 30 30 30 30 30 30 30 30 30 30 30 30 ELECTRICAL CONNECTIONS Power supply V/curve A/mm2 230/C 16/3G2.5 230/C 16/3G2.5 230/C 25/3G4 230/C 25/3G4 230/C 16/3G2.5 230/C 16/3G2.5 230/C 25/3G4 230/C 25/3G4 230/C 16/3G2.5 230/C 16/3G2.5 230/C 25/3G4 230/C 25/3G4 INDOOR UNIT Weight when empty/filled kg 10 10 10 10 34/50 34/50 34/50 34/50 130/340 130/340 130/340 130/340 HYDRAULICS SPECIFICATIONS DHW (Domestic Hot Water) ErP class / / / / / / / / A A A A Expansion tank capacity L / / / / 12 12 12 12 12 12 12 12 DHW tank capacity L / / / / / / / / 190 190 190 190 DHW electric booster heater kW / / / / / / / / 1.2 1.2 1.2 1.2 DHW tank materials / / / / / / / / enamelled steel with ACI anti-corrosion protection Heating and DHW flow diameters "in." 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 Buffer tank capacity L / / / / 16 16 16 16 16 16 16 16 Recommended operating range min./max. - hot mode °C -20/35 -20/35 -20/35 -20/35 -20/35 -20/35 -20/35 -20/35 -20/35 -20/35 -20/35 -20/35 ELECTRICAL CONNECTIONS Outdoor unit interconnection cable - Indoor unit mm2 4G1.5 4G1.5 4G1.5 4G1.5 4G1.5 4G1.5 4G1.5 4G1.5 4G1.5 4G1.5 4G1.5 4G1.5 Booster heater V/curve A/mm2 230/C 16/ 3G1.5 230/C 16/ 3G1.5 230/C 16/ 3G1.5 230/C 16/ 3G1.5 230/C 16/ 3G1.5 230/C 16/ 3G1.5 230/C 16/ 3G1.5 230/C 16/ 3G1.5 230/C 16/ 3G1.5 230/C 16/ 3G1.5 230/C 16/ 3G1.5 230/C 16/ 3G1.5 DHW booster heater V/curve A/mm2 / / / / / / / / 230/C 16/ 3G1.5 230/C 16/ 3G1.5 230/C 16/ 3G1.5 230/C 16/ 3G1.5 33 Heat pumps

RkJQdWJsaXNoZXIy NTAwMTk1