Atlantic Comfort - Heat pumps catalogue 2025

(1) Includes accessories depending on the selected solution. (2) Noise pressure at 1 m from the appliance, 1,5 m from the ground, free field, directivity index of 2. (3) Noise pressure at 5 m from the appliance, 1,5 m from the ground, free field, directivity index of 2. TECHNICAL SPECIFICATIONS AND PERFORMANCE NAME UNIT Loria Duo 6003/2C 6003 Loria Duo 6004/2C 6004 Loria Duo 6006/2C 6006 Loria Duo 6008/2C 6008 Refrigerant R32 R32 R32 R32 SPECIFICATIONS AND HEATING PERFORMANCE Energy class - heating (35°C/55°C) package - A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++ Thermal output (35°C/55°C) kW 4/4 5/5 6/5 7/6 Annual energy consumption - heating (35°C/55°C) kWh 930/1,313 2,418/3,018 2,614/3,307 2,901/3,751 Seasonal energy efficiency - heating (35°C/55°C) excluding outdoor sensor % 181/126 182/128 190/132 185/134 Seasonal energy efficiency - heating (35°C/55°C) including outdoor sensor % 183/128 184/130 192/134 187/136 Acoustic power (indoors/outdoors) dB(A) 40/57 40/57 40/57 40/60 SPECIFICATIONS AND DHW PERFORMANCE Draw-off profile - DHW - L L L L Energy class - DHW - A+ A+ A+ A+ Annual energy consumption in kWh - DHW kWh 777 777 777 777 Seasonal energy efficiency - DHW % 132 132 132 132 GENERAL SPECIFICATIONS SCOP (SEASONAL COEFFICIENT OF PERFORMANCE) 35°C/55°C 4.60/3.22 4.61/3.29 4.82/3.37 4.7/3.41 Heating capacity +7°C/+35°C - UH kW 3.30 4.60 5.60 7.50 COP (Coefficient of Performance) +7°C/+35°C - UH 5.07 4.83 4.81 4.52 Heating capacity -7°C/+35°C - UH kW 3.50 4.50 5.30 5.90 Absorbed capacity -7°C/+35°C - UH kW 1.15 1.53 1.94 2.17 COP -7°C/+35°C - UH 3.03 2.94 2.73 2.72 Heating capacity +7°C/+55°C - Rad kW 3.10 4.50 5.60 7.20 COP +7°C/+55°C - Rad 2.55 2.72 2.77 2.77 Heating capacity -7°C/+55°C - Rad kW 3.30 3.90 4.25 5.30 COP -7°C/+55°C - Rad 1.77 1.91 1.95 1.96 Electric booster heater output kW 3 3 3 3 INDOOR UNIT Noise level(2) dB(A) 32 32 32 32 Weight when empty/filled kg 135/330 135/330 135/330 135/330 HYDRAULICS SPECIFICATIONS Expansion tank capacity l 8 8 8 8 DHW tank capacity l 190 190 190 190 DHW booster heater kW 1.60 1.60 1.60 1.60 DHW tank materials Enamelled steel Warming-up time in compliance with EN16147 hr/mn 1 hr 36 mn 1 hr 36 mn 1 hr 36 mn 1 hr 36 mn Reference temperature in compliance with EN16147 °C 52.5 52.5 52.5 52.5 DHW COP in compliance with EN16147 - 3.26 3.26 3.26 3.26 Max. useable volume of hot water in compliance with EN16147 L 243 243 243 243 Reserve power in compliance with EN16147 W 31 31 31 31 Heating circuit input and output diameters (male thread) "in." 1 1 1 1 Recommended operating range min./max. - hot mode °C -20/+35 -20/+35 -20/+35 -20/+35 ELECTRICAL CONNECTION Power supply 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz Power consumption on standby W 5 5 5 5 Circuit breaker rating for heat pump booster heaters, curve C A 16 16 16 16 Heat pump booster heater power cables mm2 3G 1.5 3G 1.5 3G 1.5 3G 1.5 Circuit breaker rating for DHW booster heaters, curve C A 16 16 16 16 DHW booster heater power cable mm2 3G 1.5 3G 1.5 3G 1.5 3G 1.5 FUJITSU OUTDOOR UNIT Noise level(3) dB(A) 35 35 35 38 Weight in operation kg 39 39 39 42 REFRIGERANT SPECIFICATIONS Gas diameter "in." 1/2 1/2 1/2 1/2 Liquid diameter "in." 1/4 1/4 1/4 1/4 Refrigerant factory load, HFC-R32 g 970 970 970 1,020 Volume of fluid in tonnes of CO2-eq. t 0.65 0.65 0.65 0.69 Min./max. length m 3/30 3/30 3/30 3/30 Max. height difference m 20 20 20 20 Max. length with no additional load m 15 15 15 15 Quantity of gas to be added per additional m g 25 25 25 25 ELECTRICAL CONNECTIONS Power supply 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz Standby consumption (Average power consumed by pump) W 38 38 38 38 Max. intensity (excluding booster heaters) A 13 13 13 18 Circuit breaker rating, C curve A 16 16 16 20 Outdoor unit power cable mm2 3G1.5 3G1.5 3G1.5 3G2.5 Outdoor unit interconnection cables - Indoor unit mm2 4G1.5 4G1.5 4G1.5 4G1.5 ErP ErP 61 Heat pumps

RkJQdWJsaXNoZXIy NTAwMTk1