Installation recommendations Important to remember • Trees must be at least 5 m away from the collector • Keep non-hydraulics underground networks 1.5 m away from the collector • Maintain a minimum 3 m from the collector when it comes to building foundations, wells, septic tanks, drains and water supply outlets + wider selection Enabling horizontal collection through geothermal systems that reflects every heat pump’s specific capacity. Below, a list of Atlantic’s recommendations for each model. Geolia range Horizontal collection POTENTIAL OUTPUT UNIT Geolia 5 Geolia 7 Geolia 10 Geolia 13 Geolia 17 0°C/35°C kW 4.20 5.20 7.60 9.72 12.77 0°C/45°C kW 3.47 4.31 6.32 8.66 11.45 0°C/55°C kW - - 5.03 7.80 9.91 MODELS UNIT KIT COLLECTOR 5 KIT COLLECTOR 7/8 KIT COLLECTOR 10/12 KIT COLLECTOR 13/15 KIT COLLECTOR 17 Caps Ø 20 m 4 x 100 6 x 100 9 x 100 11 x 100 14 x 100 Pre-installed collector for Ø 20 1 1 1 1 1 Cap Ø 32 m 1 x 30 1 x 30 - - - Cap Ø 40 m - - 1 x 30 1 x 30 1 x 30 20L 30% Glycol storage container L 6 x 20 8 x 20 10 x 20 13 x 20 16 x 20 DIMENSIONS Collector length m 4 x 100 6 x 100 9 x 100 11 x 100 14 x 100 Effective surface area scoured m2 160 240 360 440 560 Effective surface area for trenching m2 120 180 270 330 420 60 cm 60 cm 60 cm 60 cm 120 cm Installation after scouring the area (single-layer collector) 40 cm min. Frost-protected depth (60 cm min.) Trench installation (dual-layer collector) 74 Heat pumps
RkJQdWJsaXNoZXIy NTAwMTk1