Side view Front view 750 820 790 650 750 820 790 650 Geolia 5, 7 and 10 kW Side view Front view 864 949 738 864 949 Geolia 13 and 17 kW DIMENSIONAL SPECIFICATIONS (mm) TECHNICAL SPECIFICATIONS AND PERFORMANCE VALUE UNIT Geolia 5 Geolia 7 Geolia 10 Geolia 13 Geolia 17 Refrigerant R410A R410A R410A R410A R410A Load g 900 950 1,450 1700 2,300 Quantity in tonnes of equivalent CO2 t 2 2 3 4 5 SPECIFICATIONS AND HEATING PERFORMANCE INCLUDING OUTDOOR SENSOR Energy class - heating (35°C/55°C) - Pure water - A+++/A+++ A+++/A+++ A+++/A+++ A+++/A+++ A+++/A+++ Thermal output (35°C/55°C) - Pure water kW 8/8 11/10 15/14 18/16 25/23 Annual energy consumption - heating (35°C/55°C) - Pure water kWh 3,138/3,973 4,323/4,997 5,225/6,242 6,912/7,576 9,057/10,272 Energy class - heating (35°C/55°C) - Glycol water - A++/- A++/- A++/- A+++/A++ A+++/A++ Thermal output (35°C/55°C) - Glycol water kW 6/- 8/- 12/- 14/13 19/18 Annual energy consumption - heating (35°C/55°C) - Glycol water kWh 3,369/- 4,074/- 5,644/- 6,386/7,546 8,604/10,337 NOMINAL SEASONAL ENERGY EFFICIENCY Product including outdoor sensor - heating (35°C/55°C) - Pure water % 213/153 196/151 233/179 212/166 219/177 Product - heating (35°C/55°C) - Pure water % 211/151 194/149 231/177 210/164 217/176 Product including outdoor sensor - heating (35°C/55°C) - Glycol water % 157/- 155/- 166/- 179/142 179/136 Product - heating (35°C/55°C) - Glycol water % 155/- 153/- 164/- 177/140 177/134 Acoustic power (indoors)(2) dB(A) 56 57 56 55 55 GENERAL SPECIFICATIONS Heating capacity +10°C+7°C/+30°C+35°C - RUH kW 7.14 9.37 13.33 16.78 22.13 Coefficient of Performance (COP) +10°C+7°C/+30°C+35°C - RUH 4.86 5.29 5.38 5.70 5.21 Heating capacity +10°C+7°C/+40°C+45°C - LTR kW 6.62 8.86 12.55 15.99 21.40 COP +10°C+7°C/+40°C+45°C - LTR 3.81 4.04 4.18 4.35 4.21 Heating capacity +10°C+7°C/+47°C+55°C - RHT kW 6.57 8.72 11.75 15.59 20.14 COP +10°C+7°C/+47°C+55°C - RHT 3.26 2.87 3.34 3.33 3.54 Heating capacity +0°C-3°C/+30°C+35°C - RUH kW 5.64 7.02 10.08 12.63 16.63 COP +0°C-3°C/+30°C+35°C - RUH 3.94 3.86 4.06 4.35 4.31 Heating capacity +0°C-3°C/+40°C +45°C - LTR kW 5.13 6.56 9.28 12.12 16.01 COP +0°C+3°C/+40°C+45°C - LTR 3.09 2.92 3.14 3.50 3.51 Heating capacity +0°C+3°C/+47°C+55°C - RHT kW - - - 11.86 15.41 COP +0°C-3°C/+47°C+55°C - RHT - - - 2.92 2.80 Electric booster heater power kW 4.5 (3 stages 1.5 kW) UNIT Noise level(3) dB(A) 49 49 49 48 48 Weight when empty/filled kg 140/145 150/155 155/160 175/180 185/190 HYDRAULICS SPECIFICATIONS Expansion tank capacity sensor L 12 12 12 18 18 Expansion tank capacity heating L 12 12 12 18 18 Minimum water volume of heating circuit L 100 120 150 200 250 Min. flow rate of heating circuit (∆T=10°C) L/h 550 700 1000 1300 1700 Min. flow rate of sensor circuit (∆T=5°C) L/h 750 900 1100 1700 2200 ELECTRICAL CONNECTIONS Power supply V/Hz 230/50 230/50 230/50 400 3ph + N 50 Power consumption on standby W 4.9 4.9 4.9 7.8 7.8 Max. compressor current(4) A 12.80 15.40 20.50 9.00 12.50 Max. heat pump current(4) A 13.30 15.90 21.00 10.00 13.50 Max. booster heater current(4) A 19.50 19.50 19.50 6.5 6.5 Max. heat pump + electric booster heater + pump current A 32.80 35.40 40.50 16.50 20.00 Cos phi 0.98 0.85 0.93(5) 0.93 0.9 Recommended heat pump circuit breaker rating (D curve)/ Recommended booster heater circuit breaker rating (C curve)(6) A 25/25 25/25 25/25 20/25 20/25 Heat pump/booster heater power supply cables mm2 3G6 / 3G6 3G6 / 3G6 3G6 / 3G6 5G2.5 / 5G6 5G2.5 / 5G6 Starter current: A < 30A < 30A > 30A < 50A < 50A HYDRAULICS CONNECTIONS Heating circuit input and output diameters (male thread) "in." 1"1/4 1"1/4 1"1/4 1"1/4 1"1/4 Sensor circuit input and output diameters (male thread) "in." 1"1/4 1"1/4 1"1/4 1"1/4 1"1/4 DHW tank output diameters "in." 3/4" 3/4" 3/4" 3/4" 3/4" OPERATING RANGE Min./max. temperature return glycol water sensor °C -10/+25°C flow, 50°C max. 0/+25°C flow, 55°C max. -7/+25°C flow, 55°C max. 0/+25°C flow, 60°C max. ErP ErP (1) Depends on model and type of collection. (2) Acoustic power of 0/35°C using EnR 12102-1 standard. (3) Noise pressure 5 m from the appliance at 0/35°C, using EN ISO 11203 standard. (4) Current given per phase for three-phase heat pump. (5) Max. tolerated impedance: 0.25 ohm. (6) Circuit breaker rating adapted according to authorised booster heater output. 78 Heat pumps

RkJQdWJsaXNoZXIy NTAwMTk1