+ simpler to install Compact product that can substitute for a wall-mounted boiler, suited to existing high-temperature heat emitters + easier to maintain Full front access to outdoor unit and wall-mounted hydraulics unit components + enhanced comfort • Atlantic Smart Adapt • Instant DHW, continuously available thanks to sustained plate heat exchanger temperatures Hybea range Wall-mounted hybrid gas heat pumps with a gas condensing booster heater and DHW micro-storage Supplies R32 inverter outdoor unit including: • Refrigerant circuit • Intuitive, optimised and whisper-quiet fan • Low-consumption circulating pump • Plate heat condenser Wall-mounted hydraulics unit • Stainless steel combustion chamber • Burner deploying Easy Gaz Control technology: automatic gas calibration (compatible with natural gas and propane) • Domestic Hot Water (DHW) stainless steel plate exchanger • Expansion tank heating (7 and 8L depending on the model) • Exhaust outlets with measuring sockets Control box • Load shedding-compatible extension board • Atlantic Smart Adapt control (optional outdoor sensor) Hydraulics compensator, sludge filter, no-return valves and flow and return sensors Exhaust outlet systems • Horizontal suction Ø 60/100 and Ø 80/125 (C13) • Vertical suction Ø 60/100 and Ø 80/125 (C33) • Commercial connector piping C10 / C43p (3CEp) / C43 (3CE) • Adaptation to existing flue piping (B23p and C93 Renolux) Packaging Delivered in 8 packages • 1 boiler package • 1 outdoor unit package • 1 wall-mounted hydraulics unit package • 1 control box package • 1 hydraulics kit package (standard accessories) • 1 tap bar + wall-mounted bracket package • 1 connector package • 1 exhaust connector package (3) 3 models (5 to 8 kW) with a 30kW burner and 3 models (5 to 8 kW) with a 35kW burner • Single-phase • Wall-mounted boiler replacement • Flue and Suction • Standard energy cost controls and coefficient of performance (COP) • High-temperature solution, up to 80°C Sizing requirements for existing buildings(1) Basic heat loss is calculated using the NF EN 12831-1 standard and France’s national addition, the NF P52-612/CN standard, with reference to building specifications. • The output of a standalone heat pump at an outdoor temperature of 0°C with a water flow temperature of 50°C(2) must account for 40% to 60% of the building’s heat loss at the proposed base outdoor temperature. • The heat pump must demonstrate capabilities to produce a water flow temperature above or equal to 55°C at an outdoor temperature of 0°C. Pairing performance with optimal spacing * Internal and outdoor units jointly designed with Fujitsu. A A+++ 35°C A++ 55°C NEW * MADE IN FRANCE 97
RkJQdWJsaXNoZXIy NTAwMTk1