with stand installation A 630 175 B Z H C Ø 440 230 Capot monophasé 15 Hot water Cold water Technical specifications and installation dimensions Model Output (W) Voltage (V) Heating time Hot water capacity at 40°C Cooling constant Energy consumption kWh/24 h Dimensions (mm) Net weight (kg) ErP energy class Profile Ø H A B Z C Zeneo Standard Vertical wall-mounted 50 1200 230 V single phase 2h23 - 0.35 0.82 505 575 370 - 172 530 23 C A+ F M 75 1200 230 V single phase 4h08 142 L 0.28 1.08 513 705 570 - 135 530 23 C A+ F M 100 1200 230 V single phase 5h27 177 L 0.27 1.28 513 835 750 - 85 530 27 C A+ F L 150 1800 230 V single phase kit for 400 V 3-phase 5h14 277 L 0.23 1.65 513 1155 1050 800 105 530 35 C A+ F M 200 2200 5h44 374 L 0.20 1.94 513 1475 1050 800 425 530 45 C A+ F L Zeneo Vertical wall-mounted turbo range 50 1800 230 V single phase kit for 400 V 3-phase 1h27 - 0.35 0.82 505 575 370 - 172 530 23 C A+ F M 75 3000 1h37 132 l 0.31 1.11 510 735 575 - 135 530 27 C A+ F M 100 3000 2h20 184 L 0.28 1.34 510 900 750 - 85 530 30 C A+ F L 150 3000 3h20 269 L 0.22 1.56 530 1200 1050 800 105 550 39 C A+ F M 200 3000 4h46 363 L 0.20 1.87 530 1515 1050 800 425 550 49 C A+ F L STAND IS REQUIRED Rotating dielectric union included Zeneo 70