Indirect and combi water heaters 1 COIL HEAT EXCHANGER 2 TANK-IN-TANK Optimised heat exchanger located at the bottom to heat the tank High-efficiency cold water inlet, preventing hot and cold water from mixing to maintain a constant water temperature The built-in coil is heated by a primary circuit connected to an external power source that heats water in the tank. If back-up is needed, an optional electric kit can be installed. The annular heat exchanger inside the tank offers a large surface for heat exchanges between water contained in the tank and the primary circuit. It also ensures a vertical or horizontal position for the water heater, depending on installation configurations. The exclusive annular heat exchanger ensures minimal pressure loss and can be operated even where no pump is fitted within the primary circuit. Exclusive annular heat exchanger to heat the tank High-efficiency cold water inlet, preventing hot and cold water from mixing to maintain a constant water temperature 72