Technical specifications Models Voltage (V) Maximum total power consumed by the device (W) Power consumed by electric heating (W) COP at 15 °C (ambient) V40 ErP (L) Heating time from 10 °C to 51 °C (ambient installation 15 °C air) (H) Acoustic power (dB(A)) Refrigerant fluid ErP Class 200 230 2250 1800 2.4 270.5 3h42 54 R290 A A+ F 250 230 2250 1800 2.66 336.6 4h34 54 R290 A A+ F 250 (with coil) 230 2250 1800 2.5 337.9 4h35 54 R290 A A+ F IPX1B Installation dimensions Models Dimensions (mm) Net weight (kg) A B C D E F 200 1180 1529 277 959 575 636 64 250 1432 1782 277 1199 575 636 71 250 (with coil) 1432 1782 277 1199 575 636 82 DESCRIPTION Batch of 10 EasyRaccord Elbows 20x27 Water collection tray Installation accessory essentials MADE IN FRANCE A A+ F HEAT PUMP WATER HEATERS 93