Your browser is not up to date and is not able to run this publication.
Learn more

TECHNICAL CHARACTERISTICS AND PERFORMANCES

(1) Sound power level is a laboratory measurement of the sound power emitted by the product, but it does not correspond to the sound perceived. Used by acoustics specialists, it allows to measure the sound pressure level of the product in its working environment. - (2) Acoustic pressure at 1m from HP, 1,5 m height, open field, directivity 2. - (3) Models with electric back-up. - (4) Acoustic pressure at 5m from HP, 1,5 m height, open field, directivity 2.

UNIT ALFEA EXTENSA DUO A.I. 3 R32 ALFEA EXTENSA DUO A.I. 5 R32

ALFEA EXTENSA DUO A.I. 6 R32

ALFEA EXTENSA DUO A.I. 8 R32

ALFEA EXTENSA DUO A.I. 10 R32

REFRIGERANT R32 R32 R32 R32 R32 ENERGY EFFICIENCY & ACOUSTIC CHARACTERISTICS

Energy class - Heating (35°C/55°C) - A+++ / A+ A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++ Rated heat power (35°C/55°C) kW

to be confirmed

5 / 5 6 / 5 7/6 9/8 Annual energy consumption - Heating (35°C/55°C) kWh 2322 / 3035  2594 / 3411 2982 / 3903 3 875 / 5 083 Seasonal energy efficiency - Heating (35°C/55°C) % 175 / 125 175 / 125 177 / 128 178 / 130 Seasonal energy efficiency - Heating (35°C/55°C) with outdoor sensor % 177 / 127 177 / 127 179 / 130 180 / 132

Sound power level (indoor/outdoor)(1) dB(A) 40 / 57 40 / 57 40 / 60 40 / 62 Declared load profile - DHW - L L L L L Energy class - DHW - A+ A+ A+ A+ A+ Annual energy consumption - DHW kWh 793 793 793 793 793 Seasonal energy efficiency (%) - DHW % 130 130 130 130 130

MAIN CHARACTERISTICS

SCOP 35 °C / 55 °C - 4.45 / 3.20 4.46 / 3.21 4.5 / 3.28 4.53 / 3.33 Heating capacity +7°C/+35°C Underfloor Heating kW

to be confirmed

4.50 5.50 7.50 9.50 COP +7°C/+35°C - Underfloor Heating 4.74 4.65 4.43 4.50 Heating capacity -7°C/+35°C Underfloor Heating kW 4.40 5.00 5.70 8.90 COP -7°C/+35°C - Underfloor Heating 2.76 2.63 2.68 2,65 Heating capacity +7°C/+45°C Low T°radiators kW 4.50 5.50 7.25 9.25 COP +7°C/+45°C Low T°radiators 3.39 3.39 3.35 3.40 Heating capacity -7°C/+45°C Low T°radiators kW 4.28 4.82 5.58 8.61 COP -7°C/+45°C Low T°radiator 2.26 2.21 2.17 2.27 Heating capacity +7°C/+55°C - Radiators kW 4.50 5.50 7.00 9.00 COP +7°C/+55°C - Radiators 2.64 2.67 2.66 2.70 Heating capacity -7°C/+55°C - Radiators kW 3.90 4.25 5.30 8.00 COP -7°C/+55°C - Radiators 1.85 1.89 1.90 1.95 Additional electric back-up heater kW 3 / 6 3 / 6 3 / 6  3 / 6  INDOOR HYDRAULIC MODULE

Noise level(2) dB(A) to be confirmed 32 32 32 34 Net weight/filled weight(3) kg 143 / 373 143 / 373  143 / 373  143 / 373 145 / 363  Power supply V/Hz 230 / 50 230 / 50 230 / 50 230 / 50 230 / 50 OUTDOOR UNIT

Noise level(4) dB(A) to be confirmed 35 35 38 38 Operating weight kg 39 43 43 46 62 REFRIGERANT CHARACTERISTICS

Min./max. length m 3 / 30 3 / 30 3 / 30 3 / 30 3 / 30 Max. difference in height m 20 20 20 20 20 R32 factory load g 970 970 970 1 020 1 630 Quantity of refrigerant in tons of CO2 equivalent t 0,65 0,65 0,65 0.69 1.10

INSTALLATION DIMENSIONS (mm)

Er P

Bottom view

Front viewSide view

886325

353 180

580

33 0

63 2

12 0 18 4

Air

8 6325

353 180

580

33 0

63 2

12 0 18 4

Air

886325

353 180

580

33 0

63 2

12 0 18 4

Air

Outdoor Inverter unit Alfea Extensa Duo A.I. R32

3.5 and 6

Bottom view

Side view Front view

907349

353 194

600

33 0

71 6

11 9 18

4

Air

907349

353 194

600

33 0

71 6

11 9 18

4

Air

907349

353 194

60

33 0

71 6

11 9 18

4

Air

Outdoor Inverter unit Alfea Extensa Duo A.I. R32 8

Outdoor Inverter unit Alfea Extensa Duo A.I. R32 10

Bottom view

Side view Front view

99 6

940365

39 1

650

35 5

Air

99 6

940365

39 1

650

35 5

Air

99 6

940365

39 1

650

35 5

Air

Front view Front view 648

297

244

47

175

18 55

18 41

18 63

144

12 95

55

11 89

11 37

210

684

16 12

16 80

648

297

244

47

175 18

55

18 41

18 63

144

12 95

55

11 89

11 37

210

684

16 12

16 80

Indoor hydraulic module

22

Heat pumps & renewableenergy solutions 2021 - AtlanticHeat pumps & renewableenergy solutions 2021 - AtlanticHeat pumps & renewableenergy solutions 2021 - AtlanticHeat pumps & renewableenergy solutions 2021 - AtlanticHeat pumps & renewableenergy solutions 2021 - AtlanticHeat pumps & renewableenergy solutions 2021 - AtlanticHeat pumps & renewableenergy solutions 2021 - AtlanticHeat pumps & renewableenergy solutions 2021 - AtlanticHeat pumps & renewableenergy solutions 2021 - AtlanticHeat pumps & renewableenergy solutions 2021 - AtlanticHeat pumps & renewableenergy solutions 2021 - AtlanticHeat pumps & renewableenergy solutions 2021 - AtlanticAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range accessoriesAlfea range accessoriesAlfea range accessoriesLoria range presentationLoria range presentationLoria range presentationLoria range presentationLoria range presentationLoria range presentationLoria range presentationLoria range presentationLoria range presentationLoria range accessoriesLoria range accessoriesWall-InWall-InAtlantic Geolia range presentationAtlantic Geolia range presentationAtlantic Geolia range presentationAtlantic Geolia range presentationPanama AccessPanama AccessPanama AccessPanama AccessPanama Access
Powered by Fluidbook