540
4 trous Ø11
62790326
352
62 0
32 0
16
11 0 17
5
AIR
AIR
540
4 trous Ø11
62790326
352
62 0
32 0
16
11 0 17
5
AIR
AIR
806
450
926 917
65 161
343
59,5
841
59,5
274,5 104,5
806
450
926 917
65 161
343
59,5
841
59,5
274,5 104,5
TECHNICAL CHARACTERISTICS AND PERFORMANCES
INSTALLATION DIMENSIONS (mm)
UNIT LORIA 6004 LORIA 6006 LORIA 6008 LORIA 6010
REFRIGERANT R410A R410A R410A R410A ENERGY EFFICIENCY CHARACTERISTICS
Energy class - Heating (35°C/55°C) A+++ / A++ A+++ / A++ A+++ A++ / A++ Rated heat output (35°C/55°C) kW 4 / 4 6 / 5 7 / 6 9/7 Annual energy consumption - Heating (35°C/55°C) kWh 1884 / 2708 2588 / 2933 3147 / 4132 4481 / 5256 Seasonal energy efficiency - Heating (35°C/55°C) % 181 / 127 186 / 128 176 / 129 154 / 116 Seasonal energy efficiency - Heating (35°C/55°C) with outdoor sensor % 183 / 129 188 / 130 178 / 131 156 / 118 Sound power level (indoor/outdoor)(1) dB(A) 44 / 62 44 / 62 44 / 69 44 / 68
MAIN CHARACTERISTICS
SCOP 35 °C / 55 °C - 4.6 / 3.25 4.72 / 3.27 4.46 / 3.30 4.22 / 3.20 Heating capacity +7°C/+35°C Underfloor Heating kW 4.00 6.00 7.50 10.42 COP +7°C/+35°C - Underfloor Heating 4.80 4.45 4.15 4.40 Heating capacity -7°C/+35°C Underfloor Heating kW 4.10 5.00 5.90 7.94 Power consumption -7°C/+35°C - Underfloor Heating kW 1.46 1.79 2.46 3.11 COP -7°C/+35°C - Underfloor Heating 2.80 2.80 2.40 2.55 Heating capacity +7°C/+45°C Low T°radiators kW 4.00 5.10 6.20 8.51 COP +7°C/+45°C Low T°radiators 3.50 3.50 3.35 3.54 Heating capacity -7°C/+45°C Low T°radiators kW 4.10 4.50 5.15 7.38 COP -7°C/+45°C Low T°radiator 2.30 2.26 2.10 2.11 Heating capacity +7°C/+55°C Low T°radiators kW 3.68 4.27 5.53 6.98 COP +7°C/+55°C Low T°radiators 2.65 2.67 2.68 2.65 Heating capacity -7°C/+55°C Low T°radiators kW 3.72 3.88 5.03 6.47 COP -7°C/+55°C Low T°radiators 1.90 1.92 1.70 1.78 Electric back-up heater kW 3 3 3 3 INDOOR HYDRAULIC MODULE
Noise level(2) dB(A) 36 36 36 36 Net weight/filled weight kg 37.5 / 41.5 37.5 / 41.5 37.5 / 41.5 37.5 / 41.5 Min./Max. outdoor temperature for heating °C -20 / +35 -20 / +35 -20 / +35 -20 / +35 Power supply V / Hz 230 / 50 230 / 50 230 / 50 230 / 50 OUTDOOR UNIT
Noise level(3) dB(A) 42 42 47 47 Operating weight kg 41 41 42 60 REFRIGERANT CHARACTERISTICS
Min./max. length m 5 / 30 5 / 30 5 / 30 5 / 30 Max. difference in height m 20 20 20 20 R410A factory load g 1100 1100 1400 1800 Quantity of refrigerant in tons of CO2 equivalent t 2 2 3 4
(1) Sound power level is a laboratory measurement of the sound power emitted by the product, but it does not correspond to the sound perceived. Used by acoustics specialists, it allows to measure the sound pressure level of the product in its working environment.
(2) Acoustic pressure at 1m from HP, 1.5 m height, open field, directivity 2. (3) Acoustic pressure at 5m from HP, 1.5 m height, open field, directivity 2.
Loria 4,6 and 8kW Ourdoor Inverter unit
Indoor hydraulic module
Side view
Bottom view
Front view
650 AIR
AIR
37 0
83 0
21 9
900 77373
400
650
AIR
AIR
37 0
83 0
21 9
900 77373
400
Loria 10kW Ourdoor Inverter unit
Er P
Front view Side viewSide view Front view
540
4 trous Ø11
62790326
352
62 0
32 0
16
11 0 17
5
AIR
AIR
Bottom view 4 holes
48