TECHNICAL CHARACTERISTICS AND PERFORMANCES
INSTALLATION DIMENSIONS (mm)
Er P
UNIT LORIA DUO 6004 LORIA DUO 6006 LORIA DUO 6008 LORIA DUO 6010
REFRIGERANT R410A R410A R410A R410A ENERGY EFFICIENCY CHARACTERISTICS
Energy class - Heating (35°C/55°C) A+++ / A++ A+++ / A++ A+++/A++ A++ / A++ Rated heat output (35°C/55°C) kW 4 / 4 6 / 5 7 / 6 9/7 Annual energy consumption - Heating (35°C/55°C) kWh 1884 / 2708 2588 / 2933 3147 / 4132 4481 / 5256 Seasonal energy efficiency - Heating (35°C/55°C) % 181 / 127 186 / 128 176 / 129 154 / 116 Seasonal energy efficiency - Heating (35°C/55°C) with outdoor sensor % 183 / 129 188 / 130 178 / 131 156 / 118 Sound power level (indoor/outdoor) (1) dB(A) 44 / 62 44 / 62 44 / 69 44 / 68 Declared load profile - DHW L L L L Energy class - DHW A+ A+ A+ A+ Annual water heating energy consumption kWh 966 966 966 966 Seasonal water heating energy efficiency (%) % 130 130 130 130 MAIN CHARACTERISTICS
SCOP 35 °C / 55 °C - 4.6 / 3.25 4.72 / 3.27 4.46 / 3.30 3.9 / 2.95 Heating capacity +7°C/+35°C Underfloor Heating kW 4.07 6.02 7.47 10.42 COP +7°C/+35°C - Underfloor Heating 4.96 4.70 4.22 4.40 Heating capacity -7°C/+35°C Underfloor Heating kW 4.42 5.20 5.96 7.94 Power consumption -7°C/+35°C - Underfloor Heating kW 1.42 1.77 2.33 3.11 COP -7°C/+35°C - Underfloor Heating 3.11 2.94 2.56 2.55 Heating capacity +7°C/+45°C Low T°radiators kW 4.09 4.98 6.40 8.51 COP +7°C/+45°C Low T°radiators 3.62 3.51 3.37 3.54 Heating capacity -7°C/+45°C Low T°radiators kW 4.24 4.62 5.74 7.38 COP -7°C/+45°C Low T°radiator 2.48 2.38 2.21 2.11 Heating capacity +7°C/+55°C Low T°radiators kW 3.68 4.27 5.53 6.98 COP +7°C/+55°C Low T°radiators 2.65 2.67 2.68 2.65 Heating capacity -7°C/+55°C Low T°radiators kW 3.72 3.88 5.03 6.47 COP -7°C/+55°C Low T°radiators 1.90 1.92 1.70 1.78 Electric back-up heater kW 3 3 3 3 INDOOR HYDRAULIC MODULE
Noise level (2) dB(A) 36 36 36 36 Net weight/filled weight kg 138 / 332 138 / 332 138 /332 138 /332 Power supply V / Hz 230 / 50 230 / 50 230 / 50 230 / 50 OUTDOOR UNIT
Noise level (3) dB(A) 40 40 47 47 Operating weight kg 41 41 42 60 REFRIGERANT CHARACTERISTICS
Min./max. length m 5 /30 5 /30 5 /30 5 /30 Max. difference in height m 20 20 20 20 HFC R410A factory load g 1100 1100 1400 1800 Quantity of refrigerant in tons of CO2 equivalent t 2 2 3 4 (1) Sound power level is a laboratory measurement of the sound power emitted by the product, but it does not correspond to the sound perceived. Used by acoustics specialists,
it allows to measure the sound pressure level of the product in its working environment. (2) Acoustic pressure at 1m from HP, 1.5 m height, open field, directivity 2. (3) Acoustic pressure at 5m from HP, 1.5 m height, open field, directivity 2.
Loria Duo 4, 6 and 8 kW Ourdoor Inverter unit
Indoor hydraulic module
Side view Front view
Loria Duo 10 kW Ourdoor Inverter unit
Side view Front view Front view Side view
Bottom viewBottom view 4 holes
52